Beta-2-Microglobulin

Message
For Specimen Integrity during Extreme Weather see the “Lockbox Usage in Extreme Weather” document at the top of this page.


Test Code
B2MC


Alias/See Also
852;
B2-MIC;
Microglobulin;
Beta2


CPT Codes
82232

Preferred Specimen
serum


Minimum Volume
0.5 mL


Other Acceptable Specimens
plasma from Lithium Heparin (Light Green Top) tube


Instructions
Barrier tubes (serum separator tubes or plasma separator tubes) are preferred. If non-barrier tubes are utilized, the serum/plasma must be removed immediately after centrifuging and placed in a screw-cap transfer tube.

Collection notes: Avoid hemolysis. Invert tubes at least 8 times. Allow to clot in an upright position for 30 minutes. Within 2 hours, centrifuge tubes 10 minutes. Keep tightly stoppered.

Do NOT re-centrifuge tubes. Do NOT freeze the primary collection tube.


Transport Container
Original tube preferred, may be sent in a screw-top transfer tube.


Transport Temperature
Refrigerated


Specimen Stability
Room Temperature = n/a
Refrigerated = 3 days
Frozen = 6 months


Reject Criteria (Eg, hemolysis? Lipemia? Thaw/Other?)
Hemolysis, Lipemia, incorrect specimen type, insufficient sample volume, improper storage conditions, exceeds specimen stability guidelines, contaminated sample.


Methodology
immunoassay

Setup Schedule
Daily
AU


Report Available
daily


Clinical Significance
Beta-2-microglobulin normally passes through the glomerulus into the proximal tubule where much of it is reabsorbed. Serum levels are therefore an index of glomerular function. When impaired, serum levels rise in inverse ratio to glomerular filtration rate. Increased amounts of beta-2-microglobulin are excreted in several renal disorders, e.g., Balkan nephropathy, heavy metal poisoning and renal tubular disease due to therapeutic agents. Serial levels of beta-2-microglobulin in serum and urine are used to evaluate transplant viability and anticipate rejection. Following a successful graft, serum levels decline toward normal. Increasing serum levels provide an early sign of rejection. Elevated levels are also noted in lymphproliferative disorders, neoplasms (malignant and benign), inflammatory disease, and autoimmune diseases such as systemic lupus erythematosus (SLE) and Sjögren's disease.


Performing Laboratory
CompuNet Clinical Laboratories, LLC
2308 Sandridge Drive
Moraine, OH 45439



The CPT Codes provided in this document are based on AMA guidelines and are for informational purposes only. CPT coding is the sole responsibility of the billing party. Please direct any questions regarding coding to the payor being billed. Any Profile/panel component may be ordered separately. Reflex tests are performed at an additional charge.