A B C D E F G H I J K L M N O P Q R S T U V W X Y Z # |
Bismuth, Blood
Test CodeBISMUT
Alias/See Also
5374
CPT Codes
83018
Preferred Specimen
4 mL whole blood collected in an EDTA trace metal-free (royal blue-top) tube
Patient Preparation
Avoid taking bismuth preparations such as Pepto-Bismol for at least 1 week prior to collection.
Minimum Volume
2 mL
Other Acceptable Specimens
Whole blood collected in: Sodium heparin trace metal-free (royal blue-top) tube or sodium heparin lead-free (tan-top) tube
Tests performed on a specimen submitted in a non-trace element tube or non acid-washed/non metal-free container may not accurately reflect the patient's level. If a non-trace element tube/container is received, it will be accepted for testing. However, elevated results shall be reported with a message that a re-submission with a trace element tube/container is recommended.
Tests performed on a specimen submitted in a non-trace element tube or non acid-washed/non metal-free container may not accurately reflect the patient's level. If a non-trace element tube/container is received, it will be accepted for testing. However, elevated results shall be reported with a message that a re-submission with a trace element tube/container is recommended.
Transport Container
EDTA trace metal-free (royal blue-top) tube
Transport Temperature
Refrigerated (cold packs)
Specimen Stability
Room temperature: 48 hours
Refrigerated: 7 days
Frozen: Unacceptable
Refrigerated: 7 days
Frozen: Unacceptable
Reject Criteria (Eg, hemolysis? Lipemia? Thaw/Other?)
Gross hemolysis • Clotted
Methodology
Inductively Coupled Plasma/Mass Spectrometry (ICP/MS)
FDA Status
This test was developed and its analytical performance characteristics have been determined by Quest Diagnostics. It has not been cleared or approved by FDA. This assay has been validated pursuant to the CLIA regulations and is used for clinical purposes.
This test code is for non-New York patient testing. For New York patient testing, see test code 13725.
Setup Schedule
Tues, Thurs, Sat
Clinical Significance
Excessive use of bismuth containing medications may cause renal damage and other adverse effects.
Performing Laboratory
med fusion |
2501 South State Hwy 121, Suite 1100 |
Lewisville, TX 75067-8188 |