Aluminum, Blood

Test Code
ALUMIN


Alias/See Also
6021


CPT Codes
82108<br><strong>This test code is for non-New York patient testing. For New York patient testing, the recommended alternative test code is 13741.</strong>

Preferred Specimen
2 mL whole blood collected in an EDTA trace metal (royal blue-top) tube


Patient Preparation
Avoid fruits, juices and tea for 24 hours before collection

Minimum Volume
1 mL


Other Acceptable Specimens
Whole blood collected in: Sodium heparin trace metal (royal blue-top) tube, heparin (green-top) tube, or EDTA (lavender-top) tube


Instructions
Carefully clean skin prior to venipuncture. Avoid hemolysis. Avoid worksite collection.


Transport Container
EDTA trace metal (royal blue-top) tube


Transport Temperature
Room temperature


Specimen Stability
Room temperature: 14 days
Refrigerated: 30 days
Frozen: 60 days


Methodology
Inductively Coupled Plasma/Mass Spectrometry (ICP/MS)

FDA Status
This test was developed and its analytical performance characteristics have been determined by Quest Diagnostics. It has not been cleared or approved by FDA. This assay has been validated pursuant to the CLIA regulations and is used for clinical purposes.

This test code is for non-New York patient testing. For New York patient testing, the recommended alternative test code is 13741.

Setup Schedule
Mon, Wed, Sat


Report Available
2-5 days


Clinical Significance
Aluminum has been found as a cause of encephalopathy in patients undergoing prolonged hemodialysis for renal failure. Patients in renal failure lose the ability to filter and excrete aluminum which consequently accumulates in the blood and eventually in the brain and in bone.


Performing Laboratory
med fusion
2501 South State Hwy 121, Suite 1100
Lewisville, TX 75067-8188




The CPT Codes provided in this document are based on AMA guidelines and are for informational purposes only. CPT coding is the sole responsibility of the billing party. Please direct any questions regarding coding to the payor being billed. Any Profile/panel component may be ordered separately. Reflex tests are performed at an additional charge.