| A B C D E F G H I J K L M N O P Q R S T U V W X Y Z # |
KAPPA/LAMBDA LC FREE SERUM(B)
MessageSENDOUT/BOSTON
Test Code
K/L LC FREE-SERUM
Alias/See Also
FREE KAPPA/LAMBDA LIGHT-CHAIN SERUM, LAMBDA-KAPPA LIGHT CHAIN SERUM, LIGHT CHAIN FREE KAPPA/LAMBDA
CPT Codes
83883x2, 83883X2
Includes
KAPPA LC FREE
LAMBDA LC FREE
FREE K/L RATIO
LAMBDA LC FREE
FREE K/L RATIO
Preferred Specimen
SERUM: GOLD TOP TUBE
Minimum Volume
2mLs
Instructions
DRAW 1 GOLD TOP SST TUBE, LET CLOT FOR 30 MINUTES, AND SPIN DOWN. SEND TO LAB.
Transport Container
ORIGINAL TUBE
Transport Temperature
REFRIGERATED
Reject Criteria (Eg, hemolysis? Lipemia? Thaw/Other?)
Reject if 3+ or 4+ lipemia/icterus/hemolysis
Methodology
Optilite/Colorimetric
Setup Schedule
M-F
Report Available
2-5 DAYS
Reference Range
Ratio 0.26 to 1.65
Free Kappa 3.30-22.50 mg/L
Free Lambda 5.71-30.50 mg/L
Free Kappa 3.30-22.50 mg/L
Free Lambda 5.71-30.50 mg/L
Clinical Significance
Elevated serum levels of monoclonal free light chains with abnormal free kappa/free lambda ratios is associated with malignant plasma cell disorders including multiple myeloma, nonsecretory multiple myeloma, light chain disease, and primary amyloidosis. This assay may also be useful in monitoring the treatment of patients previously diagnosed with multiple myeloma.
High or low ratios are suggestive of monoclonal gammopathies.
High or low ratios are suggestive of monoclonal gammopathies.
Performing Laboratory
Test performed in the West Roxbury Immunology Lab Contact: Cassandra Mota, 857-203-5941
Additional Information
KAPPA/LAMBDA LIGHT-CHAIN FREE SERUM