BLOOD CULTURE(1ST SET)

Message
MICROBIOLOGY


Test Code
BC 1ST SET


Alias/See Also
BLD CULTURE-ANAEROBIC BLD CULTURE, AEROBIC BLD CULTURE


Includes
ANAEROBIC BOTTLE, AEROBIC BOTTLE


Preferred Specimen
Blood received in BD BACTEC bottles, use both aerobic and anaerobic bottles to make 1 set.


Minimum Volume
5-10 MLS PER BOTTLE


Instructions
Hold ChloraPrep applicator with sponge facing downward and gently press sponge against skin site and apply ChloraPrep solution using back-and-forth friction scrub for 30 seconds. Allow area to dry for 30 seconds. DO NOT touch the disinfected site. Mark the vials to indicate the required fill TOTAL VOLUME.Remove the flip-off caps from the blood culture vials and wipe top of each vial with a separate 70% isopropyl alcohol pad and allow to dry. BD Vacutainer Push Button Collection Set ("butterfly") is used for collection. Draw ONE aerobic (grey cap) and one anaerobic bottle (purple cap) per order number and indicate time of collection and site on bottle and requisition.


Transport Temperature
Room temperature: ≤ 15 minutes


Specimen Stability
Room temperature: ≤ 24 hours


Reject Criteria (Eg, hemolysis? Lipemia? Thaw/Other?)
Blood not received in BD BACTEC bottles.


Methodology
BD BACTEC

Setup Schedule
DAILY


Report Available
Gram stain result as soon as bottle signals positive (16-48 hours)
5 days for Negative cultures.


Limitations
Low inoculum could lead to false negatives or longer turnaround time.


Reference Range
NO GROWTH ON CULTURE


Performing Laboratory
WHITE RIVER JUNCTION VT VA MICRBIOLOGY 802-295-9363 EXT: 5514



The CPT Codes provided in this document are based on AMA guidelines and are for informational purposes only. CPT coding is the sole responsibility of the billing party. Please direct any questions regarding coding to the payor being billed. Any Profile/panel component may be ordered separately. Reflex tests are performed at an additional charge.