HEVYLITE IgA PANEL

Message
SENDOUT/BOSTON


Test Code
HEVYLITE IgA


Alias/See Also
IMMUNOLOGY


Includes
HLC IgA KAPPA
HLC IgA LAMBDA
HLC IgA K/L RATIO


Preferred Specimen
SERUM: GOLD TOP TUBE


Minimum Volume
1mL


Instructions
DRAW 1 GOLD TOP SST TUBE, LET CLOT FOR 30 MINUTES, SPIN DOWN AND SEND TO LAB.


Transport Container
ORIGINAL TUBE


Transport Temperature
REFRIGERATED


Specimen Stability
7 DAYS


Methodology
TURBIDOMETRIC ON THE OPTILITE ANALYZER

Setup Schedule
M,W,F


Report Available
TAT 4 DAYS


Reference Range
Test Reference range
HLC IgA Kappa 0.59 - 2.98 g/L
HLC IgA Lambda 0.43 - 2.04 g/L
HLC IgA Kappa/Lambda Ratio 0.95 - 2.21


Clinical Significance
Testing used to monitor monoclonal gammopathies


Performing Laboratory
West Roxbury Immunology Lab Contact Cassandra Mota 857-203-5978

Additional Information
HEVYLITES IgA


The CPT Codes provided in this document are based on AMA guidelines and are for informational purposes only. CPT coding is the sole responsibility of the billing party. Please direct any questions regarding coding to the payor being billed. Any Profile/panel component may be ordered separately. Reflex tests are performed at an additional charge.