CORTISOL FREE, URINE, 24 HOUR
MessageNote: 24 hour urine container must have boric acid preservative
Test Code
LAB8265
CPT Codes
82530
Preferred Specimen
24 Hour Urine Container with Boric Acid Preservative

(aliquot or transfer urine into a screw cap container and note total volume)

(aliquot or transfer urine into a screw cap container and note total volume)
Patient Preparation
Discard first morning urine on day of collection. Note the time. Collect all urine voided during the next 24 hours. 10g of boric acid preservative should be added to container prior to the start of collection. Refrigerate the urine during entire collection.
See collection instructions below.
Minimum Volume
2 mL aliquot (10 mL aliquot optimal)
Instructions
- Mix the specimen well and measure the 24-hour volume (RECORD THE TOTAL TIME)
- Aliquot into transfer tube
Transport Container
Transfer tube
Transport Temperature
Refrigerate
Specimen Stability
2-8°C up to 7 days
Methodology
CIA
Setup Schedule
M, T, W, Th, F, Sa, Sun
As received; STAT testing not available
As received; STAT testing not available
Reference Range
Non-extracted: 58-403 ug/24 hours
Performing Laboratory
Alverno Central Lab