CELL COUNT WITH DIFFERENTIAL, CSF

Message
Note: It is critical that CSF be tested within 1 hour of collection if maintained at room temperature. Specimen may be held an additional hour if maintained at 2-8°C. Up to 40% cell disintigration can occur after 60 minutes.


Test Code
CSCELL (OE), CSF (LAB)


CPT Codes
89051

Includes
  • Volume
  • Appearence
  • Color
  • RBCs
  • WBCs
  • Total cell count
  • Neutrophils
  • Eosinophils
  • Lymphocytes
  • Monocytes


Preferred Specimen
Sterile container (CSF tube 3 or 4)


Patient Preparation
None

Minimum Volume
1 mL CSF


Instructions
DO NOT CENTRIFUGE


Transport Container
Sterile tube


Specimen Stability
  • 15-30°C up to 1 hour
  • 2-8°C up to 2 hours


Reject Criteria (Eg, hemolysis? Lipemia? Thaw/Other?)
  • Sample has been centrifuged
  • Grossly coagulated


Methodology
Hemocytometer

Setup Schedule
Daily as received


Report Available
STAT: <60 minutes
Routine: <4 hours


Reference Range
  • VOLUME OF CSF See report for normal ranges.
  • APPEARANCE CSF See report for normal ranges.
  • COLOR CSF See report for normal ranges.
  • RED BLOOD CELLS IN CSF Male/Female All Ages: Normal Range: 0 CUMM
  • WHITE BLOOD CELLS IN CSF Male/Female Ages >=0 Days - <1 Year: Normal Range: 0-30 CUMM Male/Female Ages >=1 Year: Normal Range: 0-5 CUMM
  • TOTAL CELL COUNTED,CSF See report for normal ranges.
  • NEUTROPHILS IN CSF Male/Female Ages >=0 Days - <1 Year: Normal Range: 0-8 % Male/Female Ages >=1 Year: Normal Range: 0-6 %
  • EOSINOPHILS IN CSF See report for normal ranges.
  • LYMPHOCYTES IN CSF Male/Female Ages >=0 Days - <1 Year: Normal Range: 5-35 % Male/Female Ages >=1 Year: Normal Range: 40-80 %
  • MONOCYTES IN CSF Male/Female Ages >=0 Days - <1 Year: Normal Range: 50-90 % Male/Female Ages >=1 Year: Normal Range: 15-45 %
  • OTHERS CSF See report for normal ranges.


Performing Laboratory
Mount Sinai Hospital
Holy Cross Hospital



The CPT Codes provided in this document are based on AMA guidelines and are for informational purposes only. CPT coding is the sole responsibility of the billing party. Please direct any questions regarding coding to the payor being billed. Any Profile/panel component may be ordered separately. Reflex tests are performed at an additional charge.