Progesterone, LC/MS

Test Code
17183


CPT Codes
84144

Preferred Specimen
1 mL serum collected in a red-top tube (no gel)


Minimum Volume
0.25 mL


Other Acceptable Specimens
Plasma collected in: EDTA (royal blue-top) tube, sodium heparin (green-top) tube, lithium heparin (green-top) tube, or EDTA (lavender-top) tube


Instructions
Collect blood in a Vacutainer® with no additives. Allow blood to clot (10-15 minutes) at room temperature. Centrifuge and separate the serum from the cells.


Transport Temperature
Refrigerated (cold packs)


Specimen Stability
Room temperature: 72 hours
Refrigerated: 14 days
Frozen: 2 years


Reject Criteria (Eg, hemolysis? Lipemia? Thaw/Other?)
Serum separator tube (SST) • Gross hemolysis


Methodology
Chromatography/Mass Spectrometry

FDA Status
This test was developed and its analytical performance characteristics have been determined by Quest Diagnostics. It has not been cleared or approved by FDA. This assay has been validated pursuant to the CLIA regulations and is used for clinical purposes.

Setup Schedule
Night Sets up 5 days a week.


Clinical Significance
This test (1) establishes the presence of a functioning corpus lutem or luteal cell function, (2) confirms basal body temperature measurements of the occurrence of ovulation (3) affords an indication of the day of ovulation, (4) assesses placental function during pregnancy.




The CPT Codes provided in this document are based on AMA guidelines and are for informational purposes only. CPT coding is the sole responsibility of the billing party. Please direct any questions regarding coding to the payor being billed. Any Profile/panel component may be ordered separately. Reflex tests are performed at an additional charge.