A B C D E F G H I J K L M N O P Q R S T U V W X Y Z # |
Histoplasma capsulatum DNA, Real-Time PCR
Test Code90249
CPT Codes
87798
Preferred Specimen
5 mL whole blood collected in an EDTA (lavender-top) tube
Minimum Volume
0.5 mL
Other Acceptable Specimens
1 mL bronchial alveolar lavage (BAL)/wash, CSF, random urine in a sterile plastic screw-cap container • 3 cubic mm tissue in a sterile plastic screw-cap container
Transport Temperature
Refrigerated (cold packs)
Specimen Stability
Room temperature: 48 hours
Refrigerated: 7 days
Frozen: 30 days
Refrigerated: 7 days
Frozen: 30 days
Reject Criteria (Eg, hemolysis? Lipemia? Thaw/Other?)
Whole blood in heparin or fixed tissue
Methodology
Real-Time Polymerase Chain Reaction
FDA Status
This test was developed and its analytical performance characteristics have been determined by Quest Diagnostics. It has not been cleared or approved by FDA. This assay has been validated pursuant to the CLIA regulations and is used for clinical purposes.
Setup Schedule
Set up: Mon-Sat; Report available: 1-2 days
Clinical Significance
To aid in the diagnosis of histoplasma pulmonary infection and disseminated disease.