HTLV I/II DNA, Qualitative, Real-Time PCR

Test Code
34177X


CPT Codes
87798 (x2)

Preferred Specimen
1 mL whole blood collected in an EDTA (lavender-top) or ACD (yellow-top) tube


Minimum Volume
0.4 mL


Instructions
Collect blood in sterile tubes with EDTA or ACD as the anticoagulant


Transport Temperature
Refrigerated (cold packs)


Specimen Stability
Room temperature: 48 hours
Refrigerated: 7 days
Frozen: 30 days


Reject Criteria (Eg, hemolysis? Lipemia? Thaw/Other?)
Whole blood anticoagulated with heparin


Methodology
Real-Time Polymerase Chain Reaction (RT-PCR)

FDA Status
This test was developed and its analytical performance characteristics have been determined by Quest Diagnostics. It has not been cleared or approved by FDA. This assay has been validated pursuant to the CLIA regulations and is used for clinical purposes.

Setup Schedule
P.M. Sets up 6 days a week.


Clinical Significance
HTLV-I/II DNA PCR is a highly specific and sensitive method used to detect HTLV-I/II proviral DNA in clinical specimens. In addition, the assay can also differentiate between HTLV-I and HTLV-II infected individuals.




The CPT Codes provided in this document are based on AMA guidelines and are for informational purposes only. CPT coding is the sole responsibility of the billing party. Please direct any questions regarding coding to the payor being billed. Any Profile/panel component may be ordered separately. Reflex tests are performed at an additional charge.