Lead (Venous)

Test Code
599


CPT Codes
83655<br><strong>This test code is for non-New York patient testing. For New York patient testing, use test code 13650.</strong>

Preferred Specimen
3 mL whole blood collected in a K2 EDTA (tan-top) tube


Minimum Volume
0.5 mL


Other Acceptable Specimens
Whole blood collected in: Sodium heparin lead-free (tan-top) tube, EDTA (royal blue-top) tube, or sodium heparin (royal blue-top) tube


Instructions
Collection material such as alcohol swabs should be lead-free. Use powderless gloves. Once washed, fingers must not come into contact with any surface.
Clean skin (area for venipuncture) with lead-free alcohol swab prior to puncture.
Avoid worksite collection.
Lead testing will not be performed on a specimen submitted in a non-trace element tube or non-acid washed/non-metal free container.


Transport Temperature
Room temperature


Specimen Stability

Room temperature: 5 days
Refrigerated: 14 days
Frozen: 60 days



Reject Criteria (Eg, hemolysis? Lipemia? Thaw/Other?)
Clotted specimen • EDTA (lavender-top) tube


Methodology
Inductively Coupled Plasma/Mass Spectrometry (ICP/MS) or Atomic Spectroscopy (AS)

FDA Status
This test was developed and its analytical performance characteristics have been determined by Quest Diagnostics. It has not been cleared or approved by the FDA. This assay has been validated pursuant to the CLIA regulations and is used for clinical purposes.

Setup Schedule
Set up: Mon-Sat; Report available: 1-2 days


Clinical Significance
Blood lead level analysis is performed to evaluate the body burden of lead.




The CPT Codes provided in this document are based on AMA guidelines and are for informational purposes only. CPT coding is the sole responsibility of the billing party. Please direct any questions regarding coding to the payor being billed. Any Profile/panel component may be ordered separately. Reflex tests are performed at an additional charge.