Lead, Capillary (NY)
Test Code13652
CPT Codes
83655<br><strong>This is for New York patient testing. For non-New York patient testing, use test code 39027.</strong>
Preferred Specimen
0.5 mL capillary blood collected in an EDTA (lavender-top) capillary tube
Minimum Volume
0.2 mL
Instructions
Collection material such as alcohol swabs should be lead-free. Use powderless gloves. For capillary collection, wash hands thoroughly with soap and dry with clean, low-lint towel. Once washed, fingers must not come into contact with any surface. Clean skin (finger or other area for venipuncture) with lead-free alcohol swab prior to puncture. Avoid worksite collection.
Transport Temperature
Room temperature
Specimen Stability
Room temperature: 5 days
Refrigerated: 14 days
Frozen: 60 days
Refrigerated: 14 days
Frozen: 60 days
Reject Criteria (Eg, hemolysis? Lipemia? Thaw/Other?)
Clotted specimen
Methodology
Inductively Coupled Plasma/Mass Spectrometry (ICP/MS) or Atomic Spectroscopy (AS)
FDA Status
This test was developed and its analytical performance characteristics have been determined by Quest Diagnostics. It has not been cleared or approved by FDA. This assay has been validated pursuant to the CLIA regulations and is used for clinical purposes.
Setup Schedule
Set up: Mon-Sat; Report available: 1 day
Clinical Significance
Blood lead level analysis is performed to evaluate the body burden of lead.