RH (D) TYPE

Test Code
LAB1702


Quest Code
792


CPT Codes
86901

Preferred Specimen
5 mL whole blood collected in an EDTA (pink-top) tube


Minimum Volume
5 mL


Other Acceptable Specimens
ACD (yellow-top) tube, red-top tube (no gel), cord blood or EDTA (lavender-top) tube


Instructions

If submitting with a CBC, HbA1c, or any other test requiring an EDTA (lavender-top) tube, please submit a separate tube for this test



Transport Container
EDTA (pink-top) tube


Transport Temperature
Room temperature


Specimen Stability
Room temperature: 72 hours
Refrigerated: 7 days
Frozen: Unacceptable


Reject Criteria (Eg, hemolysis? Lipemia? Thaw/Other?)
Gross hemolysis • Serum separator tube (SST)


Methodology
Immune Agglutination

Setup Schedule
Mon-Sat


Report Available
1-3 days


Limitations
Weak D antigen can cause variable results in different test systems.


Clinical Significance
Antibodies to antigens in the ABO and Rh systems are the most common causes of hemolytic disease of the newborn.


Performing Laboratory
Quest Diagnostics-Lenexa
10101 Renner Blvd
Lenexa , KS 66219-9752



Last Updated: August 13, 2021


The CPT Codes provided in this document are based on AMA guidelines and are for informational purposes only. CPT coding is the sole responsibility of the billing party. Please direct any questions regarding coding to the payor being billed. Any Profile/panel component may be ordered separately. Reflex tests are performed at an additional charge.