A B C D E F G H I J K L M N O P Q R S T U V W X Y Z # |
Respiratory Panel, Molecular
Test CodeLAB5911 162
Alias/See Also
RPEPM
RESP PANEL
RESPIRATORY PATHOGEN
MOLECULAR
PCR
RESP PANEL
RESPIRATORY PATHOGEN
MOLECULAR
PCR
CPT Codes
87633
Includes
ADENOVIRUS DETECTION BY PCR
CHLAMYDOPHILA PNEUMONIA DETECTION BY PCR
CORONAVIRUS DETECTION BY PCR
INFLUENZA A, PCR
INFLUENZA A H3 PCR
INFLUENZA A H1 PCR
INFLUENZA A 2009 H1 PCR
INFLUENZA B, PCR
METAPNEUMOVIRUS PCR
MYCOPLASMA PNEUMONIA PCR
PARAINFLUENZA 1 PCR
PARAINFLUENZA 2 PCR
PARAINFLUENZA 3 PCR
PARAINFLUENZA 4 PCR
RSV A PCR
RSV B PCR
RHINOVIRUS-ENTEROVIRUS PCR
EPLEX INTERNAL CONTROL
CHLAMYDOPHILA PNEUMONIA DETECTION BY PCR
CORONAVIRUS DETECTION BY PCR
INFLUENZA A, PCR
INFLUENZA A H3 PCR
INFLUENZA A H1 PCR
INFLUENZA A 2009 H1 PCR
INFLUENZA B, PCR
METAPNEUMOVIRUS PCR
MYCOPLASMA PNEUMONIA PCR
PARAINFLUENZA 1 PCR
PARAINFLUENZA 2 PCR
PARAINFLUENZA 3 PCR
PARAINFLUENZA 4 PCR
RSV A PCR
RSV B PCR
RHINOVIRUS-ENTEROVIRUS PCR
EPLEX INTERNAL CONTROL
Instructions
Preferred Collection: Mini-tip Swab in 1-3mL BD UTM (BD#220529)
Alternative: Mini-tip Swab in VTM
Alternative: Mini-Tip swab with Liquid Stuarts Media (green-top)
Unacceptable Grossly Bloody Collections; Double culturette swab (Red-top); Cotton tip swab; Wooden shaft swab; Calcium alginate swab; Swabs other than NP swab (eg, any thick shafted swab such as an oropharyngeal swab or nasal swab); Any transport media or NP swab type not listed in preferred or acceptable collection
Specimen Storage
1. Clinical specimens can be stored at room temperature (15–30 ºC) for up to 12
hours
2. Refrigerate at 2-8 ºC for up to 10 days after collection in transport media.
Transport Container
UTM Universal Transport Medium
Transport Temperature
Refrigerated
Specimen Stability
Specimen Storage
1. Clinical specimens can be stored at room temperature (15–30 ºC) for up to 12
hours
2. Refrigerate at 2-8 ºC for up to 10 days after collection in transport media.
1. Clinical specimens can be stored at room temperature (15–30 ºC) for up to 12
hours
2. Refrigerate at 2-8 ºC for up to 10 days after collection in transport media.
Reject Criteria (Eg, hemolysis? Lipemia? Thaw/Other?)
Unacceptable
Grossly Bloody Collections; Double culturette swab (Red-top); Cotton tip swab; Wooden shaft swab; Calcium alginate swab; Swabs other than NP swab (eg, any thick shafted swab such as an oropharyngeal swab or nasal swab); Any transport media or NP swab type not listed in preferred or acceptable collection
Grossly Bloody Collections; Double culturette swab (Red-top); Cotton tip swab; Wooden shaft swab; Calcium alginate swab; Swabs other than NP swab (eg, any thick shafted swab such as an oropharyngeal swab or nasal swab); Any transport media or NP swab type not listed in preferred or acceptable collection
Reference Range
Name | Result Checking Type | Values |
Adenovirus Detection by PCR | Reference Range | Not Detected |
Chlamydophia pneumonia Detection by PCR | Reference Range | Not Detected |
Coronavirus Detection by PCR | Reference Range | Not Detected |
Influenza A 2009 H1 PCR | Reference Range | Not Detected |
Influenza A H1 PCR | Reference Range | Not Detected |
Influenza A H3 PCR | Reference Range | Not Detected |
Influenza A, PCR | Reference Range | Not Detected |
Influenza B, PCR | Reference Range | Not Detected |
Metapneumovirus PCR | Reference Range | Not Detected |
Mycoplasma pneumo by PCR | Reference Range | Not Detected |
Parainfluenza 1 PCR | Reference Range | Not Detected |
Parainfluenza 2 PCR | Reference Range | Not Detected |
Parainfluenza 3 PCR | Reference Range | Not Detected |
Parainfluenza 4 PCR | Reference Range | Not Detected |
Rhinovirus-Enterovirus PCR | Reference Range | Not Detected |
RSV A PCR | Reference Range | Not Detected |
RSV B PCR | Reference Range | Not Detected |
Clinical Significance
Qualitative Nucleic Acid Multiplex in vitro diagnostic test to detect: -
-Adenovirus
-Coronavirus undifferentiated serotypes HKU1, NL63, 229E, OC43
-Human metapneumovirus
-Human rhinovirus/enterovirus
-Influenza A subtypes H1, H1-2009, H3, influenza A undifferentiated subtypes (including subtype H5N1)
-Influenza B
-Parainfluenza virus serotypes 1-4
-Respiratory syncytial virus (RSV) A & B
-Mycoplasma pneumoniae
-Chlamydia pneumoniae
This assay is not predicted to detect severe acute respiratory syndrome (SARS)-associated coronavirus, SARs CoV-2, or Middle East respiratory syndrome (MERS)-coronavirus.
ePlex platform uses eSensor technology, which is based on the principles of competitive DNA hybridization and electrochemical detection.
-Adenovirus
-Coronavirus undifferentiated serotypes HKU1, NL63, 229E, OC43
-Human metapneumovirus
-Human rhinovirus/enterovirus
-Influenza A subtypes H1, H1-2009, H3, influenza A undifferentiated subtypes (including subtype H5N1)
-Influenza B
-Parainfluenza virus serotypes 1-4
-Respiratory syncytial virus (RSV) A & B
-Mycoplasma pneumoniae
-Chlamydia pneumoniae
This assay is not predicted to detect severe acute respiratory syndrome (SARS)-associated coronavirus, SARs CoV-2, or Middle East respiratory syndrome (MERS)-coronavirus.
ePlex platform uses eSensor technology, which is based on the principles of competitive DNA hybridization and electrochemical detection.
Performing Laboratory
MWH LAB