Urine Culture

Test Code
LAB239 1230100146


Alias/See Also
URC
CULTURE
CULTURE URINE


CPT Codes
87086

Includes
URINE CULTURE
 


Preferred Specimen
 


Transferring the Urine sample using the straw


Position: Place the urine collection cup on a clean, flat surface.


Submerge Straw: Submerge the tip of the transfer straw into the collected urine specimen in the cup.


Fill Tubes:


1st - C&S Tube:  Insert the stopper end of the grey-top C&S tube into the opening of the transfer straw. Hold it in place until the tube fills completely and then remove it. Shake the tube vigorously to mix the preservative.


Note: Collect the Grey C&S vial FIRST.


2nd - Plain UA Tube (4ML): Leave the transfer straw submerged in the urine sample. Insert the stopper end of the plain UA tube into the opening of the transfer straw. Hold it in position until the tube fills completely and then remove it. Invert the UA preservative tube 8-10 times to mix the sample.


Note: if additional tests are required, additional vials may be needed


Discarding Straw: Lift the transfer straw from the cup and discard it in a sharps container after transferring all necessary samples. 


Post Collection procedures


Labeling: Label all filled tubes accurately with patient information (name, date of birth, date/time of collection) and any other required details.


Correctly document collection date/time and SOURCE. The specimen types CCU, Foley, Straight Cath are NOT interchangeable.


Collect both tubes for:


Urinalysis


Urine Eosinophil


UA with Microscopic


UA with reflex culture


Urine Culture




Collect this tube for:                                                        Collect this tube for:
Chemistry testing                                                 Miscellaneous Microbiology 

Collect and send the separate sterile container of urine for:
Send out tests
Cytology
Low volume specimens (<12ml)

 


Minimum Volume
1


Instructions
Patient collects a Clean catch Mid-Stream specimen in a sterile container


Transport Container
 


Transport


Place specimen in a transport bag. Place any additional order labels in the outside of the bag.


MWH ER and IN- Transport Urine specimens to the Lab within 2 hours


Outreach sites- Refrigerate all containers at 4°C. Transport within 6 hours.



Transport Temperature
Refrigerated


Specimen Stability
Refrigerate if specimen cup cannot be tested immediately. Specimen good for 24 hrs of collection if refrigerated


Performing Laboratory
MWH LAB



The CPT Codes provided in this document are based on AMA guidelines and are for informational purposes only. CPT coding is the sole responsibility of the billing party. Please direct any questions regarding coding to the payor being billed. Any Profile/panel component may be ordered separately. Reflex tests are performed at an additional charge.