| A B C D E F G H I J K L M N O P Q R S T U V W X Y Z # |
Yersinia Culture, Stool
Test CodeLAB1288 1230101574
Alias/See Also
PESTIS
CPT Codes
87046
Includes
CULTURE
Preferred Specimen
Stool

-Fresh stool in Para-Pak C&S

-Fresh stool in Cary Blair

Collection of stool specimens should be during the acute or diarrheal stage of intestinal infection. Patient should pass stool in sterile pan, without urine or toilet paper touching the specimen. Toilet paper may contain barium salts, which are inhibitors to some fecal pathogens.
Sterile Container - Specimens not in Para-Pak/Cary-Blair transport medium must be placed in a sterile collection container, refrigerated, and sent to the Laboratory immediately.
Para-Pak/Cary-Blair: Random stool specimen, place in a container with Para-Pak/Cary-Blair transport medium – fill up to the line on the vial. The fecal sample must be placed in appropriate preservative within 2 hours of collection.
Rectal swab: Only acceptable for pediatric patients. Sterile swab should be inserted about 1 inch past the anal sphincter to collect the specimen.
Preferred/Acceptable Source
Stool
Stool, liquid
Stool, soft
Stool, formed
Acceptable Containers:
-Fresh stool in sterile screw-top container
-Fresh stool in Para-Pak C&S
-Fresh stool in Cary Blair
Transport Container
STERILE CUP
Transport Temperature
Refrigerated
Reject Criteria (Eg, hemolysis? Lipemia? Thaw/Other?)
Unacceptable Source
Source other than stool
Unacceptable collection
Specimen received in non-sterile container or unapproved container
Specimens that have been preserved in 10% formalin, Merthiolate Formalin, Sodium Acetate Formalin, Polyvinyl Alcohol, or other fixatives cannot be used.
Stool containing barium.
Stool specimen contaminated with urine.
Stool specimen contaminated with toilet paper.
Stool specimen from a bedpan.
Leaking specimen.
Unlabeled or Mislabeled specimen.
Specimen received outside stability time frame.
Improper/incomplete identification (no patient name, MR# or DOB, or without patient label) on specimen.
Performing Laboratory
MWH LAB