O2 Saturation, Measured Arterial

Message
Performing Lab: Regions


Test Code
RH0169


Alias/See Also
Sunquest: FO2HB; Oxhemoglobin


Preferred Specimen
1.0 mL Heparinized Arterial Blood (Blood Gas Syringe)


Minimum Volume
0.5 mL


Other Acceptable Specimens
Heparinized Capillary


Instructions
Samples should be free of air bubbles, received on ice slush and run immediately. (Exceptions to the ice slush are samples received via the pneumatic tube system, as long as they are received within 30 minutes of collection.)

HP Clinics & Sartell - order CAI to Quest


Transport Container
Blood Gas Syringe


Transport Temperature
Ice Slush


Specimen Stability
Ice Slush: 1 hour
Room Temperature: 30 minutes


Reject Criteria (Eg, hemolysis? Lipemia? Thaw/Other?)
Room Temperature >30 minutes


Methodology
CO-Oximetry

Setup Schedule
Daily


Report Available
Same Day


Reference Range
96 - 100%


Clinical Significance
Oxygen saturation is a ratio, expressed as a percentage of the volume of oxygen carried to the maximum volume that can be carried by the hemoglobin. Knowledge of oxygen saturation, when combined with knowledge of oxygen content, is useful for evaluating the amount of oxygen actually available for the tissues and can be used to determine the effectiveness of oxygen therapy.




The CPT Codes provided in this document are based on AMA guidelines and are for informational purposes only. CPT coding is the sole responsibility of the billing party. Please direct any questions regarding coding to the payor being billed. Any Profile/panel component may be ordered separately. Reflex tests are performed at an additional charge.