Digoxin

Message
Performing Lab: Hudson, Lakeview, Regions, Westfields


Test Code
0201


Alias/See Also
Sunquest: DIG; Lanoxin


CPT Codes
80162

Includes
Time of Last Dose, Digoxin


Preferred Specimen
0.2 mL Serum Separator (gold-top) tube


Minimum Volume
0.1 mL


Other Acceptable Specimens
Red, Red/Gray


Instructions
Collection:
Digoxin specimens should be drawn at least six to eight hours after the last dose. If toxicity is suspected, specimens may be drawn at any time.


Transport Temperature
Refrigerated


Specimen Stability
Room Temperature: 8 hours
Refrigerated: 1 week
Frozen: 4 months


Methodology
Multi-point Immuno-rate or Immunoassay/Bichromatic Rate (Lakeview)

Setup Schedule
Daily


Report Available
Same day.


Limitations
The Digoxin Immune FAB (Digibind), which is used in the treatment of digoxin intoxication, has been found to interfere with immunoassay measurments. Digoxin measurments in patients that have been administered Digibind should be interpreted with caution.


Reference Range
0.8 - 2.0 ng/mL

Critical: >= 2.5 ng/mL


Clinical Significance
Digoxin is a widely prescribed cardiac glycoside indicated in the treatment of congestive heart failure and supraventricular arrhythmias. Digoxin measurements are used to monitor patient compliance and therapy, and to diagnose potential overdose.




The CPT Codes provided in this document are based on AMA guidelines and are for informational purposes only. CPT coding is the sole responsibility of the billing party. Please direct any questions regarding coding to the payor being billed. Any Profile/panel component may be ordered separately. Reflex tests are performed at an additional charge.