A B C D E F G H I J K L M N O P Q R S T U V W X Y Z # |
T-Spot. TB
Test CodeTSPTQ
Alias/See Also
LAB13087
CPT Codes
86481<br>Restricted Client Code
Preferred Specimen
Collection Conatiner/Tube
Preferred: Green Lithium Heparin, Whole Blood
Acceptable: Green Sodium Heparin, Whole Blood
Submission Container/Tube: Green Lithium
Heparin tube or Green Sodium Heparin tube
Specimen Volume: 9 mL
Collection Instructions: Collect blood by
venipuncture and invert (8-10 times) to ensure that the whole blood
is mixed thouroughly with the anticoagulant.
Minimum Volume
9.0 mL
Instructions
Collect blood by venipuncture into a Quest-provided Greiner 9 mL lithium heparin (green-top) tube. The tube contents must be inverted (8-10 times) to ensure that the whole blood is mixed thoroughly with the anticoagulant. Specimens must be shipped in accordance to the pre-approved logistics process established for your site. Samples received >39 hours after collection will be rejected. Date and time of draw are required and must be provided.
Note: *****This is a short stability test and requires special handling. Please see above for special collection instructions. If you have any questions, please contact Customer Service 1-800-336-3718 option 1.*****
Note: *****This is a short stability test and requires special handling. Please see above for special collection instructions. If you have any questions, please contact Customer Service 1-800-336-3718 option 1.*****
Transport Container
See instructions
Transport Temperature
Room temperature
Specimen Stability
Room temperature: 39 hours
Refrigerated: Unaccpetable
Frozen: Unacceptable
Reject Criteria (Eg, hemolysis? Lipemia? Thaw/Other?)
Anticougulant other than lithium heparin or
sodium heparin hemolized: Centtrifuged, Samples
received >39 hours after collection. Frozen or
refrigerated samples.
Methodology
Enzyme-Linked Immunosorbent Assay
Setup Schedule
Sunday - Saturday
Report Available
Next day
Reference Range
See Laboratory Report
Clinical Significance
The T-SPOT®.TB test is an in vitro diagnostic test for the detection of effector T cells that respond to stimulation by Mycobacterium tuberculosis antigens ESAT-6 and CFP 10 by capturing interferon gamma (IFN-y) in the vicinity of T cells in human whole blood collected in lithium heparin. It is intended for use as an aid in the diagnosis of M. tuberculosis infection. The T-SPOT.TB test is an indirect test for M. tuberculosis infection (including disease) and is intended for use in conjunction with risk assessment, radiography and other medical and diagnostic evaluations.
Performing Laboratory
Quest Diagnostics Nichols Institute 14225 Newbrook Drive Chantilly, VA 20153
Last Updated: February 17, 2023