D-Dimer, Plasma
Test CodeDDIQ - NOCO
CPT Codes
85379
Preferred Specimen
1.0 mL plasma from Blue Top (3.2% Na Citrate)
Minimum Volume
Full blue top tube or 1.0 mL plasma frozen
Instructions
Full blue top tube or 1.0 mL plasma frozen.
The light blue capped tubes, containing 3.2% buffered sodium citrate, used for coagulation testing must be allowed to fill completely (after filling a small air space will normally be present). For patients having a hematocrit greater than 55%, contact the hospital coagulation department to obtain a special collection tube.
The light blue capped tubes, containing 3.2% buffered sodium citrate, used for coagulation testing must be allowed to fill completely (after filling a small air space will normally be present). For patients having a hematocrit greater than 55%, contact the hospital coagulation department to obtain a special collection tube.
Specimen Stability
Whole Blood Na Cit on heparin – ambient -1 hr
Whole blood Na Cit (unopen/unspun) ambient -24 hours
Plasma Na Cit (unopen/spun) ambient -24 Hr.
Plasma Na Cit double spun and separated, Frozen –20C - 2 weeks
Whole blood Na Cit (unopen/unspun) ambient -24 hours
Plasma Na Cit (unopen/spun) ambient -24 Hr.
Plasma Na Cit double spun and separated, Frozen –20C - 2 weeks
Reject Criteria (Eg, hemolysis? Lipemia? Thaw/Other?)
Clotted Serum received instead of Sodium Citrate plasma
Specimen past stability
Frozen plasma received thawed
Underfilled or Overfilled, blood/anticoagulant ratio must be 9/1; Specimens must be between 90% -110% full
Collected in a 3.8% Sodium Citrate tube instead of 3.2% Sodium Citrate tube
Drawn in outdated/expired tube
Hemolyzed, icteric, or lipemic sample
Specimen past stability
Frozen plasma received thawed
Underfilled or Overfilled, blood/anticoagulant ratio must be 9/1; Specimens must be between 90% -110% full
Collected in a 3.8% Sodium Citrate tube instead of 3.2% Sodium Citrate tube
Drawn in outdated/expired tube
Hemolyzed, icteric, or lipemic sample
Methodology
Setup Schedule
Monday through Sunday; Continuously
Report Available
Same day
Reference Range
Refer to the Coagulation Reference Range and Critical Results documents in the Resources file on the facility test directory page.
Clinical Significance
The determination of D-Dimer is becoming a widespread tool for diagnosing thrombosis and monitoring thrombolytic therapy.
Elevated levels of D-Dimer are found in clinical conditions such as deep vein thrombosis (DVT, pulmonary embolism (PE) and disseminated intravascular coagulation (DIC). D-Dimer levels also rise during the normal pregnancy, but very high levels are associated with complications. A negative D-Dimer result when combined with a clinical assessment of low pretest probability has been shown to have a high negative predictive value for DVT or PE. D-Dimer results in human citrated plasma from IL Coagulation systems in conjunction with a clinical pretest probability (PTP) assessment model can exclude venous thromboembolism in outpatients suspected of deep venous thrombosis and pulmonary embolism.
While a positive D-Dimer alone is not diagnostic of DVT or PE, a negative D-Dimer can be used to exclude the diagnosis of venous thrombosis. There are a number of articles available that discuss the choice of cut-off value for ruling out venous thrombosis.
Elevated levels of D-Dimer are found in clinical conditions such as deep vein thrombosis (DVT, pulmonary embolism (PE) and disseminated intravascular coagulation (DIC). D-Dimer levels also rise during the normal pregnancy, but very high levels are associated with complications. A negative D-Dimer result when combined with a clinical assessment of low pretest probability has been shown to have a high negative predictive value for DVT or PE. D-Dimer results in human citrated plasma from IL Coagulation systems in conjunction with a clinical pretest probability (PTP) assessment model can exclude venous thromboembolism in outpatients suspected of deep venous thrombosis and pulmonary embolism.
While a positive D-Dimer alone is not diagnostic of DVT or PE, a negative D-Dimer can be used to exclude the diagnosis of venous thrombosis. There are a number of articles available that discuss the choice of cut-off value for ruling out venous thrombosis.