​BILIRUBIN, TOTAL AND DIRECT

Message
Chemistry


Test Code
LAB168


Alias/See Also
Bilirubin, BUBC, BILINB, Newborn Bili


CPT Codes
82247

Includes

Adult:
Total Billirubin, Conjugated Bilirubin, Unconjugated bilirubin, Calculated Direct bilirubin

Neonatal:
Newborn Conjugated & Unconjugated Bilirubin

Cord Blood:
Conjugated & Unconjugated Bilirubin


Preferred Specimen

Adult:
Light green top tube (lithium heparin plasma)

Neonatal:
Light green top tube (lithium heparin plasma)

Cord Blood:
Red top tube


Minimum Volume
Whole blood: 600 uL (one full light-green-top microtainer or two full red-top microtainers).

Serum/plasma: 300 uL plasma.


Other Acceptable Specimens

Adult:
Gold top (serum separator tube) or Red Top Acceptable

Neonatal:
Red Top Acceptable


Instructions

Adult:
Serum acceptable. Includes Conjugated, Unconjugated and "Delta" Bilirubin, if Total Bilirubin is over 1.3 mg/dl.
LAB: Separate specimen within 4 hours of collection. Protect from light. .

Neonatal:
Protect from light. Includes Conjugated Bilirubin and Unconjugated Bilirubin.

Cord Blood:
Protect from light. Includes Conjugated Bilirubin and Unconjugated Bilirubin.


Specimen Stability
Ambient: up to 4 hours.
Refrigerated: 7 days.
Frozen: 6 months.


Reject Criteria (Eg, hemolysis? Lipemia? Thaw/Other?)
​Hemolyzed, contaminated, not enough volume


FDA Status
Approved

Setup Schedule
Everyday


Report Available
Same Day


Reference Range

Adult:
Total: 0.2 - 1.3 mg/dl
Conjugated: 0.0 - 0.3 mg/dl
Unconjugated: 0.0 - 1.1 mg/dl
"Delta": 0.0 - 0.2 mg/dl

Neonatal:
Age 2 days: 6.0-7.0 mg/dl
Age 3-5 days: 4.0-12.0 mg/dl
*Note: Newborn Bilirubin is the sum of conjugated and unconjugated bilirubin.

Cord Blood:
Cord Blood Bilirubin: 0 - 1.8 mg/dl (Sum of conjugated and unconjugated bilirubin)


Performing Laboratory
​Hoag Newport/ Hoag Irvine



The CPT Codes provided in this document are based on AMA guidelines and are for informational purposes only. CPT coding is the sole responsibility of the billing party. Please direct any questions regarding coding to the payor being billed. Any Profile/panel component may be ordered separately. Reflex tests are performed at an additional charge.