Pneumonia Pathogen Panel, NAAT

Message
  1. CMS ordering guidelines for reimbursement require:
    1. For immune-competent patents panel must be ordered by ID Specialist or Pulmonologist.
    2. For immune-compromised may only be ordered by ID Specialist, Pulmonologist, Oncology or Transplant.
  2. Recommendation for patients presenting with respiratory symptoms may be screened with INFLUENZA A, B, RSV, COVID-19 [LAB5211772]. If LAB5211772 is negative and respiratory infection is still strongly suspected consult with appropriate specialist for this panel.


Test Code
LAB5210613


CPT Codes
87633

Includes


 


Preferred Specimen
BAL, Bronchial Wash, Sputum and Endotracheal Aspirates


Minimum Volume
1 mL


Other Acceptable Specimens
When multiple specimens from similar source are received testing will be performed on most appropriate
sample.


Transport Container
Sterile container



Transport Temperature
Refrigerated


Reject Criteria (Eg, hemolysis? Lipemia? Thaw/Other?)
• Only 1 specimen will be tested if multiple samples from same patient received.
• Repeat testing on same patient will not occur <15 days from previous same source testing.


Methodology
NAAT

FDA Status
Approved

Setup Schedule
Daily


Report Available
HHNB ~4 Hours, 24/7
HHI ~6 Hours, will require sample transport to HHNB


Reference Range
Not Detected


Performing Laboratory
Hoag Newport



The CPT Codes provided in this document are based on AMA guidelines and are for informational purposes only. CPT coding is the sole responsibility of the billing party. Please direct any questions regarding coding to the payor being billed. Any Profile/panel component may be ordered separately. Reflex tests are performed at an additional charge.