Lidocaine Level

Message
Sendout, UCI test code: XLIDO (performed by ARUP)


Test Code
LAB685


Alias/See Also
Xylocaine
XLIDO


CPT Codes
80176, 99001

Preferred Specimen
1 mL serum from a red tube


Minimum Volume
0.5 mL


Other Acceptable Specimens
Dark green (sodium heparin) tube


Instructions
Separate serum from cells within 2 hours.


Transport Container
Plastic vial


Transport Temperature
Frozen


Specimen Stability
Frozen (preferred): 1 month
Refrigerated: 1 week 
Ambient: 1 week 


Reject Criteria (Eg, hemolysis? Lipemia? Thaw/Other?)
Specimens that exceed stated stability, unlabeled/mislabeled/mismatched specimens, specimens submitted in leaking containers, specimen collected in serum separator tube


Methodology
Immunoassay

FDA Status
Approved

Setup Schedule
Sunday through Saturday


Report Available
Within 24 hours upon receipt at ARUP


Reference Range
Included with report


Performing Laboratory
ARUP Laboratories, Salt Lake City, Utah

Additional Information
Lidocaine


The CPT Codes provided in this document are based on AMA guidelines and are for informational purposes only. CPT coding is the sole responsibility of the billing party. Please direct any questions regarding coding to the payor being billed. Any Profile/panel component may be ordered separately. Reflex tests are performed at an additional charge.