Lithium Level

Message
Chemistry


Test Code
LAB29


CPT Codes
80178

Includes
Lithium


Preferred Specimen
Gold top (serum separator tube)


Minimum Volume
Whole blood: 600 uL (TWO full red-top).

Serum: 300 uL


Other Acceptable Specimens
Red tube


Instructions
LAB: Separate specimen within 4 hours of collection. 


Specimen Stability
Ambient: up to 8 hours.
Refrigerated: 24 hours.
Frozen: 6 months.
Freeze for longer storage if analysis is delayed beyond 24 hours


Reject Criteria (Eg, hemolysis? Lipemia? Thaw/Other?)
Lithium heparin plasma UNACCEPTABLE


Setup Schedule
Everyday


Report Available
Same day


Reference Range
Therapeutic: 0.6 - 1.2 mmol/L Toxic: Greater than 1.5 mmol/L Severly Toxic: Greater than 2.5


Performing Laboratory
Hoag Newport/ Hoag Irvine



The CPT Codes provided in this document are based on AMA guidelines and are for informational purposes only. CPT coding is the sole responsibility of the billing party. Please direct any questions regarding coding to the payor being billed. Any Profile/panel component may be ordered separately. Reflex tests are performed at an additional charge.