Streptococcus pneumoniae IgG Antibodies, 23 Serotypes, Serum

Message
Sendout, Mayo test code: PN23M


Test Code
LAB5210654


Alias/See Also
Pneumococcal Antibody (IgG) 23 Serotype Panel
Strep Antibodies
Strep Pneumo Antibodies
Strep Pneumoniae Antibody
Strep Vaccine
Streptococcus Pneumoniae
Vaccine
PN23M


CPT Codes
86317 x 23

Preferred Specimen
Collect 0.5mL serum from a serum gel tube


Minimum Volume
0.4 mL


Instructions
Centrifuge and aliquot serum into plastic vial


Transport Container
Plastic vial


Transport Temperature
Refrigerated


Specimen Stability
Refrigerated (preferred): 21 days
Frozen: 21 days


Reject Criteria (Eg, hemolysis? Lipemia? Thaw/Other?)
Gross hemolysis Reject
Gross lipemia Reject
Gross icterus Reject


Methodology
Bead-Based Multiplex Immunoassay

Setup Schedule
4 to 6 days


Report Available
Monday through Friday


Limitations
The humoral immune response to Streptococcal pneumoniae vaccination is affected by multiple factors, including age, immune status, vaccination history, prior infections, and carrier status.

Protective concentrations of IgG antibodies, or those required to prevent infection from S. pneumoniae, have not been defined for any serotype.

Quantitation of the IgG antibody response to pneumococcal serotypes does not provide any information on the functional capacity of the serotype-specific antibodies generated (opsonization efficiency).

IgG antibodies specific for the 23 serotypes included in PPSV23 are measured in this test; except for serotype 6A, IgG antibodies specific for all the serotypes in PCV13, PCV15, and PCV20 are measured in this test.


Reference Range
Included with report


Clinical Significance
Assessing the IgG antibody response to active immunization with nonconjugated, 23-valent pneumococcal vaccines
 
Assessing the IgG antibody response to active immunization with conjugated 13-valent, 15-valent and 20-valent pneumococcal vaccines
 
Determining the ability of an individual to produce an antibody response to polysaccharide antigens, as part of the evaluation for humoral or combined immunodeficiencies


Performing Laboratory
Mayo Clinic Laboratories, Rochester, Minnesota

Additional Information
Streptococcus pneumoniae IgG Antibodies, 23 Serotypes, Serum


The CPT Codes provided in this document are based on AMA guidelines and are for informational purposes only. CPT coding is the sole responsibility of the billing party. Please direct any questions regarding coding to the payor being billed. Any Profile/panel component may be ordered separately. Reflex tests are performed at an additional charge.