SEMEN ANALYSIS

Test Code
LAB216


Alias/See Also
Semen Analysis


CPT Codes
89310

Preferred Specimen
Semen

 


Patient Preparation
Patient should have 2-7 days of sexual abstinence at the time of semen collection for accurate results
 

Instructions
Forms: If not ordering electronically, submit a General Request Form (Supply T239) with the specimen. Include the following information: semen volume, viscosity, pH, appearance (color), and number of days of sexual abstinence. Specimen must arrive within 24 hours of collection. Send specimen Monday through Thursday only and not the day before a holiday. If holiday falls on a Saturday, holiday will be observed on the preceding Friday. Sunday holidays are observed on the following Monday. Specimen should be collected and packaged as close to shipping time as possible. Laboratory does not perform testing on weekends. Patient should have 2 to 7 days of sexual abstinence at the time of semen collection for accurate results.


Transport Container
Semen Analysis Kit (Supply T178)


Transport Temperature
Ambient


Methodology
Manual

Setup Schedule
Set Up:Monday through Friday; 6:30 a.m. to 3:30 p.m. Report Available:4-5 hours/STAT 1 hour


Reference Range
Semen Analysis   Appearance: normal Volume: > or =1.5 mL pH: > or =7.2 Motile/mL: > or =6.0 x 10(6) Sperm/mL: > or =15.0 x 10(6) Motility: > or =40% Grade: > or =2.5 Motile/ejaculate: > or =9.0 x 10(6) Viscosity: > or =3.0 Agglutination: > or =3.0 Supravital: > or =58% live Fructose: positive


Clinical Significance
Determining male fertility status Semen specimens can vary widely in the same man from specimen to specimen. Semen parameters falling outside of the normal ranges do not preclude fertility for that individual.




The CPT Codes provided in this document are based on AMA guidelines and are for informational purposes only. CPT coding is the sole responsibility of the billing party. Please direct any questions regarding coding to the payor being billed. Any Profile/panel component may be ordered separately. Reflex tests are performed at an additional charge.