A B C D E F G H I J K L M N O P Q R S T U V W X Y Z # |
POTASSIUM
Test CodeLAB114
Alias/See Also
K
CPT Codes
84132
Preferred Specimen
Green Top/Gel LiHep
Minimum Volume
2.0 mL
Other Acceptable Specimens
Pediatric Green
Pediatric SST
Pediatric SST
Transport Container
PST
Transport Temperature
Refrigerate
Reject Criteria (Eg, hemolysis? Lipemia? Thaw/Other?)
Hemolysis
Methodology
Ion-Selective Electrode(ISE)
Setup Schedule
Set Up:Daily Report Available:Routine 4 hr/ STAT 1hr
Reference Range
3.3-5.1 mEq/L |
Clinical Significance
Potassium measurements are used to monitor electrolyte balance in the diagnosis and treatment of disease conditions characterized by low or high blood potassium levels.
Performing Laboratory
GBMC Chemistry