Plasma Cell Myeloma Prognostic FISH Panel

Test Code
LAB6571


Alias/See Also
PCM Prognostic Panel


CPT Codes
88374*7 Automated

Preferred Specimen
  • Bone Marrow Aspirate: 1-2 mL sodium heparin tube. EDTA tube is acceptable.
  • Peripheral Blood: Plasma cell enrichment was not validated using peripheral blood; therefore, it is not recommended as a screening specimen unless increased plasma cells are seen on blood smear. 2-5mL sodium heparin tube. EDTA tube is acceptable.
  • Fresh, Unfixed Tissue: Tissue in RPMI
  • Bone Marrow/ Peripheral Blood Smear or Fresh Tissue Touch Preparation Slides: minimum 7 slides labeled with specimen type.
  • Fluids: Equal parts RPMI to specimen volume. 
  • Fixed Cell Suspension: A client fixed cell suspension may be submitted for testing as long as it is received in 3:1 Methanol: Glacial Acetic Acid.
  • Paraffin Block or Cut Slide: N/A


Minimum Volume
1-2 mL


Instructions
Refrigerate specimen. Do not freeze. 

 


Transport Container
Use cold pack for transport, making sure cold pack is not in direct contact with specimen. Specimens should be received in our laboratory within 72 hours of collection.


Report Available
3-5 days. Add 3-5 days if reflexed.


Clinical Significance
Probes: 1p-, 1q+, iso(1q): CDKN2C (1p32), CKS1B (1q21) | FGFR3/IgH t(4;14) | CCND1/IgH t(11;14) | 13q- (13q14, 13q34) | IgH/MAF t(14;16) | IgH/MAFB t(14;20) |17p- (TP53 17p13.1, NF1 17q11.2) Probes may be ordered separately. 
Disease(s): Plasma cell myeloma, multiple myeloma
Note: Plasma cell enrichment will be performed on bone marrow samples unless our client directs us otherwise. (Peripheral blood is not recommended as a screening specimen unless increased plasma cells are seen on blood smear.) Specimens should be received in our laboratory within 72 hours of collection.
 


Performing Laboratory
Neogenomics Laboratories



The CPT Codes provided in this document are based on AMA guidelines and are for informational purposes only. CPT coding is the sole responsibility of the billing party. Please direct any questions regarding coding to the payor being billed. Any Profile/panel component may be ordered separately. Reflex tests are performed at an additional charge.