A B C D E F G H I J K L M N O P Q R S T U V W X Y Z # |
UR Drugs of Abuse 8 NC
MessageThe screening results are to be used for medical purposes only.
Please notify the laboratory within 24 hours if confirmatory testing is required.
Please notify the laboratory within 24 hours if confirmatory testing is required.
Test Code
LAB6205
Alias/See Also
DA8NC
Includes
Amphetamines screen – detects d-amphetamine, d-methamphetamine. The assay also detects l‑amphetamine, l‑methamphetamine, d,l-amphetamine, d,l-methamphetamine, methylenedioxyamphetamine (MDA), and, to a lesser extent, methylenedioxymethamphetamine (MDMA) and methylenedioxyethylamine (MDEA).
Barbiturates screen - detects both long-acting (phenobarbital) and short-acting (secobarbital, pentobarbital) barbiturates
Benzodiazepines screen - detects most benzodiazepines and their metabolites
Cannabinoids screen - detects 11-nor- Δ9 –THC-9-carboxylic acid and other Δ9 –THC metabolites
Cocaine screen – detects benzoylecgonine (cocaine metabolite)
Methadone screen - detects methadone
Opiates Screen - detects morphine, morphine-3-glucuronide, and codeine in human urine. Also detects synthetic opiates such as hydromorphone, hydrocodone, oxymorphone, oxycodone, dihydrocodeine, meperidine, and levorphanol and the narcotic antagonist nalorphine
PCP screen - detects phencyclidine
Barbiturates screen - detects both long-acting (phenobarbital) and short-acting (secobarbital, pentobarbital) barbiturates
Benzodiazepines screen - detects most benzodiazepines and their metabolites
Cannabinoids screen - detects 11-nor- Δ9 –THC-9-carboxylic acid and other Δ9 –THC metabolites
Cocaine screen – detects benzoylecgonine (cocaine metabolite)
Methadone screen - detects methadone
Opiates Screen - detects morphine, morphine-3-glucuronide, and codeine in human urine. Also detects synthetic opiates such as hydromorphone, hydrocodone, oxymorphone, oxycodone, dihydrocodeine, meperidine, and levorphanol and the narcotic antagonist nalorphine
PCP screen - detects phencyclidine
Minimum Volume
1 ml
Instructions
Collect random urine in a clean plastic screw top container without preservative.
Specimen Stability
Refrigerate within 2 hours. Stable for 3 days refrigerated.
Methodology
Two point rate:The concentration of drug in the urine sample is directly propotional to measured enzyme activity.
Limitations
The opiates reagent has cross-reactivity with the semi-synthetic opioids including
oxycodone at 1979 ng/mL and hydrocodone at 250 ng/mL
oxycodone at 1979 ng/mL and hydrocodone at 250 ng/mL
Reference Range
Negative
A negative result indicates that the drug level is below the cut-off concentration:
Amphetamines 1000 ng/mL
Barbiturates 200 ng/mL
Benzodiazepines 200 ng/mL
Cannabinoids 20 ng/mL
Cocaine 300 ng/mL
Methadone 300 ng/mL
Opiates 300 ng/mL
Phencyclidine 25 ng/mL
A negative result indicates that the drug level is below the cut-off concentration:
Amphetamines 1000 ng/mL
Barbiturates 200 ng/mL
Benzodiazepines 200 ng/mL
Cannabinoids 20 ng/mL
Cocaine 300 ng/mL
Methadone 300 ng/mL
Opiates 300 ng/mL
Phencyclidine 25 ng/mL