Candida auris colonization

Test Code
LAB3561


Alias/See Also
Candida auris Surveillance, Molecular Detection, PCR; c. auris; C auris


CPT Codes
87481

Preferred Specimen
ESwab® Liquid Based Collection and Transport/ ESwab® collection and transport system.
Composite bilateral axilla/groin swabs in 1 mL Liquid Amies.
Do not use calcium alginate swabs, as they may contain substances that inhibit PCR testing.
Collected specimens can be stored up to 48 hours at room temperature or up to seven (7) days at 2-8°C. After seven (7) days at 2-8°C, specimens may be frozen at ≤ -70 °C in accordance with the transport media instructions for use.


Minimum Volume
1 eSwab


Instructions
Single swab axilla and groin composite collection method:
Rub both sides of the swab tip over the left axilla 
skin surface and then the right, targeting the crease 
in the skin where the arm meets the body (i.e., 
swab both armpits, swiping back and forth ~5 times per armpit).
With the same swab used on the axilla, rub both sides of the swab tip 
over the left groin skin surface, targeting the inguinal crease in the skin 
where the leg meets the pelvic region and repeat with the right side 
(i.e., swab the skin of both hip creases swiping back and forth ~5 times 
per hip crease)


Transport Container
Remove the cap from the swab collection tube, then place the soft end of the collection swab into the tube. Be careful to keep the cap from touching any materials that may contaminate your sample and cap the tube.


Transport Temperature
Room Temperature


Specimen Stability
Can be stored up to 48 hours at room temperature or up to seven (7) days at 2-8°C.


Reject Criteria (Eg, hemolysis? Lipemia? Thaw/Other?)
No swab present • Calcium Alginate or Dry Swabs • Blood samples • Urine samples


Methodology
PCR

Setup Schedule
Daily


Report Available
24 Hours




The CPT Codes provided in this document are based on AMA guidelines and are for informational purposes only. CPT coding is the sole responsibility of the billing party. Please direct any questions regarding coding to the payor being billed. Any Profile/panel component may be ordered separately. Reflex tests are performed at an additional charge.