| A B C D E F G H I J K L M N O P Q R S T U V W X Y Z # |
APTT Mixing Study
Test CodeLAB326
Alias/See Also
1231500015
CPT Codes
85730 85390
Includes
PTT NORMAL CONTROL
APTT PATIENT
APTT 1:1 MIX
INCUBATED APTT CONTROL
INCUBATED APTT PATIENT
INCUBATED APTT 1:1 MIX
APTT MIXING STUDY INTERPRETATION
APTT PATIENT
APTT 1:1 MIX
INCUBATED APTT CONTROL
INCUBATED APTT PATIENT
INCUBATED APTT 1:1 MIX
APTT MIXING STUDY INTERPRETATION
Preferred Specimen
Blue Top (Sodium Citrate) tube
Minimum Volume
Fully collected Blue top tube
Instructions
Fully collect a Blue Top (sodium citrate) tube. Mix sample immediately by gentle inversion at least six times.
Transport Temperature
Refrigerated: 4 hours
Frozen: >4 hours
Frozen: >4 hours
Specimen Stability
Refrigerated: 4 hours
Frozen: >4 hours
Frozen: >4 hours
Reject Criteria (Eg, hemolysis? Lipemia? Thaw/Other?)
Underfilled tubes will not be accepted
Methodology
ACL TOP 750
FDA Status
For tests that use an in vitro diagnostic (IVD) that has been cleared or approved by the FDA
Setup Schedule
Sun-Sat
Reference Range
SEE RESULT REPORT
Clinical Significance
Coagulation mixing study with normal pooled plasma to differentiate coagulation factor deficiencies from circulating inhibitors (lupus anticoagulant).
Performing Laboratory
LITTLE ROCK LABORATORY
Last Updated: November 3, 2026