| A B C D E F G H I J K L M N O P Q R S T U V W X Y Z # |
D Dimer Quantitative
Test Code3040002502
Alias/See Also
1231500004
CPT Codes
85379
Includes
D DIMER QUANTITATIVE
INSTRUMENT DIMER
INSTRUMENT DIMER
Preferred Specimen
Blue Top (Sodium Citrate) tube
Minimum Volume
Fully collect blue top tube
Instructions
Fully collect a Blue Top (sodium citrate) tube. Mix sample immediately by gentle inversion at least six times.
Transport Temperature
Refrigerated: 4 hours
Frozen: >4 hours
Frozen: >4 hours
Specimen Stability
Refrigerated: 4 hours
Frozen: >4 hours
Frozen: >4 hours
Reject Criteria (Eg, hemolysis? Lipemia? Thaw/Other?)
Underfilled tubes
Methodology
NR Sysmex CS2500 AR, CW, HS, MV Sysmex CA660 CW Sysmex CA660-1 NR CA600
FDA Status
For tests that use an in vitro diagnostic (IVD) that has been cleared or approved by the FDA
Setup Schedule
Sun-Sat
Reference Range
Males/Females:
<500.00 ng/mL (FEU)
<500.00 ng/mL (FEU)
Clinical Significance
Quantitative fibrin degradation product measurement used to rule out deep vein thrombosis (DVT), pulmonary embolism (PE), and DIC.
Performing Laboratory
ARKADELPHIA LABORATORY CONWAY LABORATORY HEBER SPRINGS LABORATORY NORTH LITTLE ROCK LABORATORY STUTTGART LABORATORY MALVERN LABORATORY
Last Updated: November 3, 2026