Iron

Test Code
LAB94


Alias/See Also
1231100134


CPT Codes
83540

Includes
IRON


Preferred Specimen
CLINIC COLLECTIONS: Green Lithium Heparin tube (Gel separator preferred)


Minimum Volume
CLINIC COLLECTIONS: 0.5 mL plasma


Instructions
CLINIC COLLECTIONS: Collect 0.5 ml plasma in Green Lithium Heparin tube (Gel separator preferred). Must be spun within 2 hours after collection. If no gel separator, plasma must be pulled off cells within 2 hours.

If collecting with AST, ALT, VD25, K+, or LDH, label routes to Gold/SST. Collect 1.0 mL of serum in Gold/SST. Must be spun within 2 hours after collection.


Transport Temperature
Refrigerated


Specimen Stability
Room temperature (20 to 25°C): 10 hours
Refrigerated (2 to 8°C): 7 days
Freezer (-20°C): 12 months


Methodology
Abbott Alinity

Reference Range
Males:
31-144 ug/dL
Females:
25-156 ug/dL


Performing Laboratory
LITTLE ROCK LABORATORY HEBER SPRINGS LABORATORY FORT SMITH LABORATORY NORTH LITTLE ROCK LABORATORY


Last Updated: August 26, 2026


The CPT Codes provided in this document are based on AMA guidelines and are for informational purposes only. CPT coding is the sole responsibility of the billing party. Please direct any questions regarding coding to the payor being billed. Any Profile/panel component may be ordered separately. Reflex tests are performed at an additional charge.