Culture, Catheter tip

Test Code
CULTURE,CATHETER TIP


Alias/See Also

 


Preferred Specimen
The following lines: Arterial, Catheter Tip, Central, Dialysis, Femoral Catheter, Hickman, Internal Jugluar (IJ), Intro, Pacer tip, peripheral IV, PICC, port-a-cath, subclavian, swan ganz, Tessio cath, triple lumen


Minimum Volume
5 cm of distal tip of catheter.
 


Instructions
Meticulous sterile technique needed to obtain specimen.
Send 5 cm of distal catheter.
No large pieces of catheter tips
Sterile container.


Transport Temperature
Room temperature: ≤ 2 hours


Specimen Stability
Refrigerate (2-8°C): ≤ 4 hours


Reject Criteria (Eg, hemolysis? Lipemia? Thaw/Other?)
Urine Foley Catheters


Setup Schedule
Daily


Report Available
TAT
1 - 2 days


Reference Range
No Growth on Culture


Performing Laboratory
Test performed in the West Roxbury Microbiology Laboratory
Contact: Scott Connolly 857-203-5954


Last Updated: August 18, 2022


The CPT Codes provided in this document are based on AMA guidelines and are for informational purposes only. CPT coding is the sole responsibility of the billing party. Please direct any questions regarding coding to the payor being billed. Any Profile/panel component may be ordered separately. Reflex tests are performed at an additional charge.