Lidocaine

Message
This test is currently only available in BHS CPRS. If you are a Bedford provider and wish to see this test offered in Bedford CPRS- please contact the Bedford Laboratory.

Testing performed at Quest Diagnostics.


Test Code
LIDOCAINE(O)


CPT Codes
80176

Preferred Specimen
1 mL serum collected in a red-top tube (no gel)


Patient Preparation
Collect as a trough just prior to next dose

Minimum Volume
0.2 mL


Other Acceptable Specimens
Plasma collected in: EDTA (lavender-top) tube, sodium heparin (green-top) tube, or sodium fluoride/oxalate (gray-top) tube


Instructions
Collect as trough prior to next dose.


Transport Container
Transport tube


Transport Temperature
Room temperature


Specimen Stability
Room temperature: 5 days
Refrigerated: 7 days
Frozen: 30 days


Reject Criteria (Eg, hemolysis? Lipemia? Thaw/Other?)
Serum separator tube (SST)


Methodology
Immunoassay (IA)

Setup Schedule
Set up: Mon-Sat; Report available: 1-2 days


Reference Range
1.5-5.0 mg/L


Clinical Significance
Lidocaine direct injection or infusion is used in the emergency treatment of ventricular arrhythmias caused by acute myocardial infarction, open-heart surgery. It is also used for topical anesthesia administered as a gel or by injection. Lidocaine levels are monitored to assure adequate therapeutic levels are achieved and to avoid toxicity.



Last Updated: September 23, 2014


The CPT Codes provided in this document are based on AMA guidelines and are for informational purposes only. CPT coding is the sole responsibility of the billing party. Please direct any questions regarding coding to the payor being billed. Any Profile/panel component may be ordered separately. Reflex tests are performed at an additional charge.