He4 Ovarian Cancer Monitoring

Test Code
LAB8664


CPT Codes
86316

Preferred Specimen
Red no-additive no-gel


Minimum Volume
0.3 mL


Instructions
Sample collected in a red-top tube must be allowed to clot for at least 30 minutes but no longer than 1 hour


Transport Temperature
Frozen


Specimen Stability
Room temperature: 48 hours
Refrigerated: 72 hours
Frozen: 28 days


Methodology
Chemiluminescent Microparticle Immunoassay (CMIA)



The CPT Codes provided in this document are based on AMA guidelines and are for informational purposes only. CPT coding is the sole responsibility of the billing party. Please direct any questions regarding coding to the payor being billed. Any Profile/panel component may be ordered separately. Reflex tests are performed at an additional charge.