Thyrotropin Receptor Antibody, Serum

Test Code
TRAB


Alias/See Also

Antibodies to TSH receptor
Inhibitory Immunoglobulin
Long-Acting Thyroid Stimulator (LATS)
TBII (TSH-Binding Inhibiting Immunoglobulin)
Thyroid-Stimulating Hormone Receptor (TSH Receptor) Antibody
TRAb (Thyrotropin Receptor Antibody)
TSH (Thyroid-Stimulating Hormone) Receptor Binding
TSH Binding Inhibition Index
TSH Receptor (Thyroid-Stimulating Hormone Receptor) Antibody
TSH-Binding Inhibiting Immunoglobulin (TBII)
 



CPT Codes
83520

Preferred Specimen


2.0 mL of whole blood or 1.0 mL of serum




Minimum Volume


1.0 mL of whole blood or 0.5 mL of serum




Transport Container
SST Tube (gold top) or No Additive Red Top


Transport Temperature
Refrigerated


Specimen Stability


Refrigerated: 7 days
Frozen: 30 days




Reject Criteria (Eg, hemolysis? Lipemia? Thaw/Other?)
Gross Hemolysis


Methodology

Electrochemiluminescence Immunoassay



Setup Schedule
Monday through Saturday


Report Available
Report available within 3 days of receipt at Mayo Medical Laboratories


Reference Range


< or =1.75 IU/L




Clinical Significance


Recommended first-line test for detection of thyrotropin receptor (TSHR) antibodies, and used in the following situations:



-Differential diagnosis of etiology of thyrotoxicosis in patients with  ambiguous clinical findings and/or contraindicated (eg, pregnant or breast-feeding) or nondiagnostic thyroid radioisotope scans



-Diagnosis of clinically suspected Graves disease (eg, extrathyroidal manifestation of Graves disease include endocrine exophthalmos, pretibial myxedema, thyroid acropachy) in patients with normal thyroid function tests



-Determining the risk of neonatal thyrotoxicosis in a fetus of a pregnant female with active or past active Graves disease



-Differential diagnosis of gestational thyrotoxicosis versus first trimester manifestation or recurrence of Graves disease



-Assessing the risk of Graves disease relapse after antithyroid drug treatment







The CPT Codes provided in this document are based on AMA guidelines and are for informational purposes only. CPT coding is the sole responsibility of the billing party. Please direct any questions regarding coding to the payor being billed. Any Profile/panel component may be ordered separately. Reflex tests are performed at an additional charge.