Ehrlichia chaffeensis DNA 1135

Test Code
EHRLICH


Alias/See Also
EHRLICH


CPT Codes
87798

Preferred Specimen
0.7 mL whole blood collected in an EDTA (lavender-top), or acid citrate dextrose ACD (yellow-top) tube, or
1 tick (in 70% ethanol) submitted in a sterile, leak-proof container


Minimum Volume
1


Other Acceptable Specimens
1 mL CSF submitted in a sterile, leak-proof container


Instructions
Collect 1 full lavender, refrig. CSF or tick also accepted.


Transport Container
LAV


Transport Temperature
R


Specimen Stability
Room temperature: 48 hours
Refrigerated: 7 days
Frozen: 30 days


Reject Criteria (Eg, hemolysis? Lipemia? Thaw/Other?)
Hemolysis • Lithium heparin (green-top) tube • Sodium heparin (green-top) tube


Methodology
Real-Time Polymerase Chain Reaction

FDA Status
This test was developed and its analytical performance characteristics have been determined by Quest Diagnostics. It has not been cleared or approved by FDA. This assay has been validated pursuant to the CLIA regulations and is used for clinical purposes.

Setup Schedule
Set up: Mon-Sat; Report available: 1-3 days


Reference Range
Not detected


Clinical Significance
Ehrlichia chaffeensis DNA PCR is a highly sensitive method to detect the presence of ehrlichia chaffeensis DNA in clinical specimens.
The diagnosis of ehrlichia chaffeensis infection should not rely solely upon the result of PCR assay. A positive result should be considered in conjunction with clinical presentation and additional established clinical tests. Moreover, this assay cannot differentiate between viable and nonviable organisms. A negative PCR result indicates the absence of ehrlichia chaffeensis DNA at detectable levels in the sample tested and does not exclude the diagnosis of disease.


Performing Laboratory
Quest Diagnostics Nichols Institute
14225 Newbrook Drive
Chantilly, VA 20153



The CPT Codes provided in this document are based on AMA guidelines and are for informational purposes only. CPT coding is the sole responsibility of the billing party. Please direct any questions regarding coding to the payor being billed. Any Profile/panel component may be ordered separately. Reflex tests are performed at an additional charge.