A B C D E F G H I J K L M N O P Q R S T U V W X Y Z # |
JC Polyoma Virus QNT CSF 16442
Test CodeJCPVCSF
Alias/See Also
JCPVCSF
CPT Codes
87799
Preferred Specimen
0.7 mL CSF collected in a sterile, leak-proof container
Minimum Volume
0.3 mL
Instructions
0.7 ML CSF submitted in a leakproof container. Send frozen.
Transport Container
CSF 3
Transport Temperature
F
Specimen Stability
Room temperature: 48 hours
Refrigerated: 7 days
Frozen: 30 days
Refrigerated: 7 days
Frozen: 30 days
Methodology
Real-Time Polymerase Chain Reaction
FDA Status
This test was developed and its analytical performance characteristics have been determined by Quest Diagnostics. It has not been cleared or approved by the U.S. Food and Drug Administration. This assay has been validated pursuant to the CLIA regulations and is used for clinical purposes.
Setup Schedule
Set up: Daily; Report available: 1 day
Reference Range
JC Virus DNA, QN PCR, CSF | Not Detected (IU/mL) |
JC Virus DNA, QN PCR, CSF | Not Detected (Log IU/mL) |
Clinical Significance
JC Polyoma Virus is the cause of Progressive Multifocal Leukoencephalopathy (PML), a severe demyelinating disease of the central nervous system. PML is a particular concern for individuals infected with the human immunodeficiency virus. Quantification of JC virus DNA is based upon the real-time PCR amplification and detection of JCV genomic DNA. Reportable range is 50 to 50,000,000 IU/mL (1.70 to 7.70 Log IU/mL).
Performing Laboratory
Quest Diagnostics Nichols Institute
14225 Newbrook Dr
Chantilly, VA 20153