Kidney Biopsy

Message
Testing performed by Nephropath


Test Code
3941166


CPT Codes
88305-Surgical pathology; 88313x3-Special stains, each; 88346x10-Immunofluorescence, each antibody; 88348-Electron microscopy

Includes
Includes hematoxylin-and-eosin stain, periodic acid-schiff stain, periodic acid methenamine silver stain, trichrome stain, immunofluorescent studies, and electron microscopy.  


Preferred Specimen
Submit only 1 of the following specimens:

Fresh Tissue
Container/Tube: Sterile towel, sterile Petri dish, or sterile container(s)
Specimen Volume: Fresh tissue (2 blocks each 1 cm in length) with no added fixative
Forms: Surgical Pathology Request Form
Collection Instructions: 1. Label towel/dish/container with patient’s name (first and last) and date and actual time of collection. 2. Notify histology technician or pathologist that specimen has been brought to Surgical Pathology Laboratory.

Fixed Tissue
Container/Tube: Sterile container(s)
Specimen Volume: Fixed tissue
Forms: Surgical Pathology Request Form
Collection Instructions: 1. Specimen may be obtained either by open biopsy in operating room or by needle biopsy in ultrasound room. 2. Ideally, 3 pieces of tissue are needed. Place 1 piece in Zenker’s fixative for light microscopy, 1 in cold glutaraldehyde fixative for electron microscopy, and another in Duboscq-Brazil fixative. 3. Label container with patient’s name (first and last) and date and actual time of collection. 4. Notify histology technician or pathologist that specimen has been brought to Surgical Pathology Laboratory.


Instructions
Call CoxHealth Laboratories at 417-269-7820 to schedule test.


Transport Temperature
Ambient


Methodology
Direct Immunofluorescence/Electron Microscopy/Light Microscopy

Setup Schedule
Monday through Friday


Reference Range
An interpretive report will be provided.


Clinical Significance
Useful for evaluation of chronic renal disease.  


Performed By
CoxHealth



The CPT Codes provided in this document are based on AMA guidelines and are for informational purposes only. CPT coding is the sole responsibility of the billing party. Please direct any questions regarding coding to the payor being billed. Any Profile/panel component may be ordered separately. Reflex tests are performed at an additional charge.