Lamellar Body Count (LBC), Amniotic Fluid

Message
This test was developed and its performance characteristics determined by Cox Laboratory. This test has not been cleared or approved by the U.S. Food and Drug Administration.  


Test Code
495


CPT Codes
83664

Preferred Specimen

Container/Tube: Sterile container(s)
Specimen Volume: 2.5 mL of fresh, uncontaminated amniotic fluid
Collection Instructions: Obtain by transabdominal amniocentesis. However, amniotic fluid obtained from a vaginal pool can be used. Grossly contaminated specimen should be centrifuged for 3 minutes at 1,500 rpm.
Protect specimen from light. 




Transport Temperature
Refrigerate


Methodology
Sysmex XN-3000, platelet count by impedance

Setup Schedule
Monday through Sunday


Reference Range
Immature: <15,000 /mm³
Transitional: 15,000-50,000 /mm³
Mature: >50,000 /mm³


Performed By
CoxHealth



The CPT Codes provided in this document are based on AMA guidelines and are for informational purposes only. CPT coding is the sole responsibility of the billing party. Please direct any questions regarding coding to the payor being billed. Any Profile/panel component may be ordered separately. Reflex tests are performed at an additional charge.