Glucose, 2-Hour Postprandial, Plasma or Serum

Message
The 2-hour post-load (75 g) glucose determination is considered the best single specimen for diabetes screening 


Test Code
544


CPT Codes
82950

Preferred Specimen
Submit only 1 of the following specimens:

Plasma
Container/Tube: Green-top (heparin) tube(s)
Specimen Volume: 3 mL (minimum volume: 0.5 mL) of plasma
Collection Instructions: Draw blood in the morning after an overnight fast as follows:
    1. Patient should consume an adequate meal or glucose load 2 hours before test as specified by patient’s physician.
    2. Patient is allowed usual meal (breakfast or lunch).
    3. Patient must complete meal within 15 to 20 minutes.
    4. Specimen is to be drawn 2 hours from beginning of meal.
    5. It is preferable to administer 75 g glucose, allowing 5 minutes for consumption.
Note: 1. Indicate plasma. 2. Label specimen appropriately (plasma).

Serum
Container/Tube: Serum gel tube(s)
Specimen Volume: 3 mL (minimum volume: 0.5 mL) of serum
Collection Instructions: Draw blood in the morning after an overnight fast as follows:
    1. Patient should consume an adequate meal or glucose load 2 hours before test as specified by patient’s physician.
    2. Patient is allowed usual meal (breakfast or lunch).
    3. Patient must complete meal within 15 to 20 minutes.
    4. Specimen is to be drawn 2 hours from beginning of meal.
    5. It is preferable to administer 75 g glucose, allowing 5 minutes for consumption.
Note: 1. Indicate serum. 2. Label specimen appropriately (serum).


Transport Temperature
Refrigerate


Methodology
Hexokinase

Setup Schedule
Monday through Sunday


Reference Range
2-HOUR GLUCOSE
Two 2-hour postprandial glucose results >=200 mg/dL are considered diagnostic of diabetes mellitus


Performed By
CoxHealth



The CPT Codes provided in this document are based on AMA guidelines and are for informational purposes only. CPT coding is the sole responsibility of the billing party. Please direct any questions regarding coding to the payor being billed. Any Profile/panel component may be ordered separately. Reflex tests are performed at an additional charge.