A B C D E F G H I J K L M N O P Q R S T U V W X Y Z # |
Acetyl Fentanyl, Qualitative, Urine
Test Code91829
CPT Codes
80354
Preferred Specimen
5 mL urine submitted in a plastic, leak-proof urine container
Minimum Volume
1 mL
Transport Temperature
Room temperature
Specimen Stability
Room temperature: 5 days
Refrigerated: 7 days
Frozen: 30 days
Refrigerated: 7 days
Frozen: 30 days
Methodology
Liquid Chromatography/Tandem Mass Spectrometry (QTrap)
Setup Schedule
Set up: Mon-Sat a.m.; Report available: 2 days
Reference Range
Negative
Clinical Significance
Acetyl fentanyl is a fentanyl analog previously undocumented in illicit drug use that is up to five times more potent than heroin. Acetyl fentanyl's enhanced potency has led to a number of reported deaths due to overdose. The Centers for Disease Control (CDC) recommends laboratories to provide analytical options for acetyl fentanyl in order to provide enhanced surveillance for healthcare providers.
Performing Laboratory
Quest Diagnostics Nichols Institute
14225 Newbrook Drive
Chantilly, VA 20153