Posaconazole

Test Code
POSAC


Alias/See Also

LAB11747



CPT Codes
<p>80187</p>

Preferred Specimen

Specimen Type: Serum Red


Collection Container/Type: Red top


Submission Container/Tube: Plastic vial


Specimen Volume: 2 mL



Minimum Volume

1 mL



Transport Temperature
Refrigerated (cold packs)


Specimen Stability

Room temperature: 72 hours


Refrigerated: 14 days


Frozen: 30 days



Reject Criteria (Eg, hemolysis? Lipemia? Thaw/Other?)

Serum separator tubes (SST) • Other body fluids • Other specimen types



Methodology

Liquid Chromatography/Tandem Mass Spectrometry (LC/MS/MS)

This test was developed and its analytical performance characteristics have been determined by Quest Diagnostics. It has not been cleared or approved by FDA. This assay has been validated pursuant to the CLIA regulations and is used for clinical purposes.



FDA Status
This test was developed and its analytical performance characteristics have been determined by Quest Diagnostics. It has not been cleared or approved by FDA. This assay has been validated pursuant to the CLIA regulations and is used for clinical purposes.

Setup Schedule
Set up: Tues, Thurs, Sat.; Report available: 1-4 days


Report Available

2-5 days



Reference Range
after 7 days of treatment
Target for prophylaxis purposetrough level >0.7 mcg/mL
Target for salvage treatmenttrough level >1.25 mcg/mL


Clinical Significance
The antifungal drug posaconazole is indicated for prophylaxis of invasive aspergillus and candida infections in severely immunocompromised patients. It may also be used in the treatment of oropharyngeal candidiasis refractory to itraconazole and fluconazole. The chronic nature of fungal infections demands constant monitoring of posaconazole levels within a patient to ensure that adequate therapeutic levels of the drug are administered, absorbed and subsequently excreted.


Performing Laboratory
Quest Diagnostics Nichols Institute 14225 Newbrook Drive Chantilly, VA 20153


Last Updated: February 17, 2023


The CPT Codes provided in this document are based on AMA guidelines and are for informational purposes only. CPT coding is the sole responsibility of the billing party. Please direct any questions regarding coding to the payor being billed. Any Profile/panel component may be ordered separately. Reflex tests are performed at an additional charge.